WCS_DISPATCHER

WCS task dispatch — one task per request to the best-placed available machine, with round-robin aisle balancing.

Validated application blockMHE · WMS/WCS IntegrationIEC 61131-3IEC 61499v1.0.0

When to use it

Use WCS_DISPATCHER when a queue of ready warehouse tasks has to be handed one at a time to whichever crane, shuttle or AGV is idle and in range, and the same task must never be given to two machines.

Interface

The published port signature. This is the whole of what the block exposes to your program — the implementation body is not shown here and ships with the download.

Inputs

PortType
ENABLEBOOL
REQBOOL
TASK_QUINT
HEAD_TASKUINT
EQ_STATUSUINT
EQ_COUNTUSINT
PRIORITYUSINT
MIN_PRIORITYUSINT
HOST_OKBOOL
BALANCEBOOL
NO_EQ_TMOTIME
ACKBOOL

Outputs

PortType
NEXT_EQUINT
NEXT_TASKUINT
DISPATCHEDBOOL
DISPATCH_VALIDBOOL
DISPATCH_COUNTUDINT
AVAIL_COUNTUSINT
ASSIGN_PENDINGBOOL
HOLDINGBOOL
ALM_NO_EQBOOL
ALM_NO_TASKBOOL
ALM_HOST_DOWNBOOL
ALM_CFG_ERRBOOL

IEC 61499 event interface

EI INIT, REQ·EO INITO, CNF

Validation evidence

Tests
10
Simulated scans
93
Simulator
v0.1.0

Complete IEC 61131-3 implementation with a published test suite that runs on the vplant simulator. The counts above are that suite, executed on this build.

  • Conforms to IEC 61131-3
  • Conforms to IEC 61499