One-up/one-down lot genealogy: each input lot linked to the output lot it went into, sealed into a chain, with a mass balance per output lot and a permissive withheld until the genealogy exists.

Validated application blockF&B · Food SafetyIEC 61131-3IEC 61499v1.0.0

When to use it

Use TRACEABILITY_LINK when a batch, a fill run or a converting job consumes identified input lots into an identified output lot, and the traceability programme has to answer 'what went into this?' and 'where did this go?' within the time a withdrawal allows.

Interface

The published port signature. This is the whole of what the block exposes to your program — the implementation body is not shown here and ships with the download.

Inputs

PortTypeUnit
ENABLEBOOL
LINK_REQBOOL
LOT_INSTRING
LOT_OUTSTRING
QTYREALkg
ACKBOOL

Outputs

PortTypeUnit
LINK_HASHSTRING
TRACE_OKBOOL
LINKED_LOT_INSTRING
LINKED_LOT_OUTSTRING
LINKED_QTYREALkg
OUT_LOT_QTYREALkg
IN_LOT_COUNTUDINT
LINK_COUNTUDINT
REJ_COUNTUDINT
REJECT_CODEUSINT
ALM_REJECTEDBOOL
VALIDBOOL

IEC 61499 event interface

EI INIT, REQ·EO INITO, CNF

Validation evidence

Tests
10
Simulated scans
111
Simulator
v0.1.0

Complete IEC 61131-3 implementation with a published test suite that runs on the vplant simulator. The counts above are that suite, executed on this build.

  • Conforms to IEC 61131-3
  • Conforms to IEC 61499