TRACEABILITY_LINK

One-up/one-down lot genealogy: each input lot linked to the output lot it went into, sealed into a chain, with a mass balance per output lot and a permissive withheld until the genealogy exists.

Validated application blockF&B · Food SafetyIEC 61131-3v1.0.0

When to use it

Use TRACEABILITY_LINK when a batch, a fill run or a converting job consumes identified input lots into an identified output lot, and the traceability programme has to answer 'what went into this?' and 'where did this go?' within the time a withdrawal allows.

Interface

The published port signature. This is the whole of what the block exposes to your program — the implementation body is not shown here and ships with the download.

Inputs

PortTypeUnit
ENABLEBOOL—
LINK_REQBOOL—
LOT_INSTRING—
LOT_OUTSTRING—
QTYREALkg
ACKBOOL—

Outputs

PortTypeUnit
LINK_HASHSTRING—
TRACE_OKBOOL—
LINKED_LOT_INSTRING—
LINKED_LOT_OUTSTRING—
LINKED_QTYREALkg
OUT_LOT_QTYREALkg
IN_LOT_COUNTUDINT—
LINK_COUNTUDINT—
REJ_COUNTUDINT—
REJECT_CODEUSINT—
ALM_REJECTEDBOOL—
VALIDBOOL—

Validation evidence

Tests
10
Simulated scans
111
Simulator
v0.1.0

Complete IEC 61131-3 implementation with a published test suite that runs on the vplant simulator. The counts above are that suite, executed on this build.

  • Conforms to IEC 61131-3

Download TRACEABILITY_LINK — free

Create a free Ri Tech account to download the block. You get the Structured Text body, the Rockwell Add-On Instruction (.L5X), the Schneider Control Expert DFB (.XDB), PLCopen XML and the datasheet.

Every block in the catalogue is free to download, in every format it ships, with no purchase and no card. Browsing needs no account at all; downloading needs a signed-in one, so the block lands in your library and re-downloads whenever you need it.