Double-seam integrity monitoring on thickness, height and overlap, with a sampling-plan watchdog.

Validated application blockF&B · FillingIEC 61131-3IEC 61499v1.0.0

When to use it

Use SEAMER_MON when a can seamer's double seam is measured — on-line by a seam monitor or off-line by teardown or seam scope — and the results have to hold the seamer rather than merely be recorded.

Interface

The published port signature. This is the whole of what the block exposes to your program — the implementation body is not shown here and ships with the download.

Inputs

PortTypeUnit
ENABLEBOOL
CHECKBOOL
SEAM_THICKREALmm
SEAM_HEIGHTREALmm
OVERLAP_PCTREAL%
MEAS_OKBOOL
THICK_MINREALmm
THICK_MAXREALmm
HEIGHT_MINREALmm
HEIGHT_MAXREALmm
OVERLAP_MINREAL%
CHECK_INTERVALTIME
ACKBOOL

Outputs

PortType
SEAM_OKBOOL
SEAMER_HOLDBOOL
MEAS_VALIDBOOL
ALM_THICKBOOL
ALM_HEIGHTBOOL
ALM_OVERLAPBOOL
ALM_SEAM_FAILBOOL
ALM_CHECK_OVERDUEBOOL
CHECK_DUEBOOL
ALM_MEAS_FAULTBOOL
ALM_CFG_ERRBOOL
CHECKS_DONEUDINT
FAILSUDINT
VOID_CHECKSUDINT

IEC 61499 event interface

EI INIT, REQ·EO INITO, CNF

Validation evidence

Tests
6
Simulated scans
82
Simulator
v0.1.0

Complete IEC 61131-3 implementation with a published test suite that runs on the vplant simulator. The counts above are that suite, executed on this build.

  • Conforms to IEC 61131-3
  • Conforms to IEC 61499

Download SEAMER_MON — free

Create a free Ri Tech account to download the block. You get the Structured Text body, the Rockwell Add-On Instruction (.L5X), the Schneider Control Expert DFB (.XDB), PLCopen XML, the IEC 61499 function block type (.fbt) and the datasheet.

Every block in the catalogue is free to download, in every format, with no purchase and no card. Browsing needs no account at all; downloading needs a signed-in one, so the block lands in your library and re-downloads whenever you need it.

Source is never published on this page. The implementation is released to a signed-in Ri Tech account — free of charge, but never anonymously.