PASTEURIZER_CTRL

HTST pasteuriser hold-tube supervision with flow diversion below the legal cut-in temperature.

Validated application blockF&B · ThermalIEC 61131-3IEC 61499v1.0.0

When to use it

Use PASTEURIZER_CTRL when a continuous HTST pasteuriser holds product in a hold tube and a flow diversion valve must send product forward only while the hold-tube outlet temperature has been at or above the legal cut-in temperature for the full residence time.

Interface

The published port signature. This is the whole of what the block exposes to your program — the implementation body is not shown here and ships with the download.

Inputs

PortTypeUnit
ENABLEBOOL
PROD_TREAL°C
TEMP_OKBOOL
SPREAL°C
DIVERT_TREAL°C
HOLD_TTIME
ACKBOOL

Outputs

PortTypeUnit
STV_POSBOOL
IN_SPECBOOL
DIVERTEDBOOL
HOLD_PROVENBOOL
ALM_UNDER_TEMPBOOL
ALM_TEMP_FAULTBOOL
ALM_CFG_ERRBOOL
DIVERT_TIME_SREALs

IEC 61499 event interface

EI INIT, REQ·EO INITO, CNF

Validation evidence

Tests
9
Simulated scans
200
Simulator
v0.1.0

Complete IEC 61131-3 implementation with a published test suite that runs on the vplant simulator. The counts above are that suite, executed on this build.

  • Conforms to IEC 61131-3
  • Conforms to IEC 61499

Download PASTEURIZER_CTRL — free

Create a free Ri Tech account to download the block. You get the Structured Text body, the Rockwell Add-On Instruction (.L5X), the Schneider Control Expert DFB (.XDB), PLCopen XML, the IEC 61499 function block type (.fbt) and the datasheet.

Every block in the catalogue is free to download, in every format, with no purchase and no card. Browsing needs no account at all; downloading needs a signed-in one, so the block lands in your library and re-downloads whenever you need it.

Source is never published on this page. The implementation is released to a signed-in Ri Tech account — free of charge, but never anonymously.