OCS_MONITOR

Overhead contact system monitor: definite-time under/over-voltage to EN 50163, auto-tensioner deviation and contact-wire temperature, each with its own validity.

Validated application blockTransit · Station & WaysideIEC 61131-3IEC 61499v1.1.0

When to use it

Use OCS_MONITOR when the overhead contact system or conductor rail along a section is instrumented for line voltage, tensioner load and wire temperature, and the control centre needs those three watched against limits rather than merely trended.

Interface

The published port signature. This is the whole of what the block exposes to your program — the implementation body is not shown here and ships with the download.

Inputs

PortTypeUnit
ENABLEBOOL
PARAMSSTRING
LINE_V_INREALV
V_OKBOOL
TENSION_INREALkN
TENS_OKBOOL
TEMP_INREALdegC
TEMP_OKBOOL
UV_VREALV
OV_VREALV
V_DELAYTIME
TENS_NOMREALkN
TENS_TOL_PCTREAL%
TENS_DELAYTIME
TEMP_HIREALdegC
TEMP_HYSTREALdegC
ACKBOOL

Outputs

PortTypeUnit
LINE_VREALV
TENSION_OKBOOL
TEMPREALdegC
V_VALIDBOOL
TEMP_VALIDBOOL
TENS_VALIDBOOL
TENS_DEV_PCTREAL%
OCS_OKBOOL
ALM_UVBOOL
ALM_OVBOOL
ALM_TENSIONBOOL
ALM_TEMP_HIBOOL
ALM_MEAS_FAULTBOOL
ALM_CFG_ERRBOOL

IEC 61499 event interface

EI INIT, REQ·EO INITO, CNF

Validation evidence

Tests
11
Simulated scans
185
Simulator
v0.1.0

Complete IEC 61131-3 implementation with a published test suite that runs on the vplant simulator. The counts above are that suite, executed on this build.

  • Conforms to IEC 61131-3
  • Conforms to IEC 61499

Download OCS_MONITOR — free

Create a free Ri Tech account to download the block. You get the Structured Text body, the Rockwell Add-On Instruction (.L5X), the Schneider Control Expert DFB (.XDB), PLCopen XML, the IEC 61499 function block type (.fbt) and the datasheet.

Every block in the catalogue is free to download, in every format, with no purchase and no card. Browsing needs no account at all; downloading needs a signed-in one, so the block lands in your library and re-downloads whenever you need it.

Source is never published on this page. The implementation is released to a signed-in Ri Tech account — free of charge, but never anonymously.