OCPP_SESSION

OCPP 1.6/2.0.1 charging-session state machine with metered transaction energy and smart-charging profile enforcement.

Validated application blockEV · Fleet & DepotIEC 61131-3IEC 61499v1.0.0

When to use it

Use OCPP_SESSION when a charge point has to authorise a presented identifier, open and close a metered transaction, and enforce the power ceiling a central system or local load manager sends down as a ChargingProfile.

Interface

The published port signature. This is the whole of what the block exposes to your program — the implementation body is not shown here and ships with the download.

Inputs

PortTypeUnit
ENABLEBOOL
ID_TAGSTRING
PLUGGEDBOOL
AUTH_ACCEPTEDBOOL
LOCAL_AUTH_OKBOOL
OFFLINEBOOL
AUTH_TMOTIME
METER_WHREALWh
METER_OKBOOL
PROFILE_ACTIVEBOOL
PROFILE_KWREALkW
LOCAL_MAX_KWREALkW
STOP_REQBOOL
STOP_HOLDTIME
TX_ID_MAXUINT
ACKBOOL

Outputs

PortTypeUnit
TX_IDUINT
STATUSUSINT
ENERGY_WHREALWh
ENERGY_VALIDBOOL
OFFER_KWREALkW
CHARGINGBOOL
AUTHORIZEDBOOL
ALM_AUTH_FAILBOOL
ALM_METER_FAULTBOOL
ALM_CFG_ERRBOOL

IEC 61499 event interface

EI INIT, REQ·EO INITO, CNF

Validation evidence

Tests
12
Simulated scans
212
Simulator
v0.1.0

Complete IEC 61131-3 implementation with a published test suite that runs on the vplant simulator. The counts above are that suite, executed on this build.

  • Conforms to IEC 61131-3
  • Conforms to IEC 61499

Download OCPP_SESSION — free

Create a free Ri Tech account to download the block. You get the Structured Text body, the Rockwell Add-On Instruction (.L5X), the Schneider Control Expert DFB (.XDB), PLCopen XML, the IEC 61499 function block type (.fbt) and the datasheet.

Every block in the catalogue is free to download, in every format, with no purchase and no card. Browsing needs no account at all; downloading needs a signed-in one, so the block lands in your library and re-downloads whenever you need it.

Source is never published on this page. The implementation is released to a signed-in Ri Tech account — free of charge, but never anonymously.