LABEL_REGISTRATION

Label registration-mark alignment with deadband trim of the applicator offset and drift detection.

Validated application blockF&B · FillingIEC 61131-3v1.0.0

When to use it

Use LABEL_REGISTRATION when a labeller applies pre-printed or wrap-around labels cut to a registration mark, the mark position is measured per label, and the applicator start position has to be trimmed to keep the cut on the mark.

Interface

The published port signature. This is the whole of what the block exposes to your program — the implementation body is not shown here and ships with the download.

Inputs

PortTypeUnit
ENABLEBOOL—
SAMPLEBOOL—
MARK_POSREALmm
TARGETREALmm
TOLREALmm
MARK_SEENBOOL—
MEAS_OKBOOL—
GAINREALfraction
OFFSET_MAXREALmm
DRIFT_TMOTIME—
MISS_LIMUSINT—
ACKBOOL—

Outputs

PortTypeUnit
APPLIED_OKBOOL—
REJECTBOOL—
OFFSET_CMDREALmm
ERROR_MMREALmm
AT_LIMITBOOL—
APPLY_PERMITBOOL—
VALIDBOOL—
LABELSUDINT—
REJECTSUDINT—
MISSESUDINT—
ALM_NO_MARKBOOL—
ALM_REG_DRIFTBOOL—
ALM_MEAS_FAULTBOOL—
ALM_CFG_ERRBOOL—

Validation evidence

Tests
8
Simulated scans
66
Simulator
v0.1.0

Complete IEC 61131-3 implementation with a published test suite that runs on the vplant simulator. The counts above are that suite, executed on this build.

  • Conforms to IEC 61131-3