DATE_LOT_VERIFY

Date and lot code print-and-verify against the expected code, with a blank-code check and a verifier watchdog.

Validated application blockF&B · FillingIEC 61131-3IEC 61499v1.0.0

When to use it

Use DATE_LOT_VERIFY when a coder prints a date and lot code on every pack and a vision or OCR reader reads it back, and product may not be released unless the printed code has been proved to match the code the batch record says it should carry.

Interface

The published port signature. This is the whole of what the block exposes to your program — the implementation body is not shown here and ships with the download.

Inputs

PortType
ENABLEBOOL
READ_DONEBOOL
EXPECTEDSTRING
READSTRING
CAM_OKBOOL
LINE_RUNBOOL
FAIL_LIMUSINT
READ_TMOTIME
ACKBOOL

Outputs

PortType
MATCHBOOL
REJECTBOOL
LINE_PERMITBOOL
VALIDBOOL
VERIFIEDUDINT
FAILEDUDINT
CONSEC_FAILSUSINT
ALM_NO_CODEBOOL
ALM_CODE_FAILBOOL
ALM_VERIFY_LOSTBOOL
ALM_CAM_FAULTBOOL
ALM_CFG_ERRBOOL

IEC 61499 event interface

EI INIT, REQ·EO INITO, CNF

Validation evidence

Tests
8
Simulated scans
73
Simulator
v0.1.0

Complete IEC 61131-3 implementation with a published test suite that runs on the vplant simulator. The counts above are that suite, executed on this build.

  • Conforms to IEC 61131-3
  • Conforms to IEC 61499

Download DATE_LOT_VERIFY — free

Create a free Ri Tech account to download the block. You get the Structured Text body, the Rockwell Add-On Instruction (.L5X), the Schneider Control Expert DFB (.XDB), PLCopen XML, the IEC 61499 function block type (.fbt) and the datasheet.

Every block in the catalogue is free to download, in every format, with no purchase and no card. Browsing needs no account at all; downloading needs a signed-in one, so the block lands in your library and re-downloads whenever you need it.

Source is never published on this page. The implementation is released to a signed-in Ri Tech account — free of charge, but never anonymously.